The Definitive Guide to Dp50rb
The Definitive Guide to Dp50rb
Blog Article
1.2.two Warning Labels Warning Labels That means Be sure to very carefully read through this handbook just before use system. The next labels undoubtedly are a. Will not area the system on the sloped surface. Otherwise the accessible if the technique gadget may slide, causing personal injury or maybe the gadget operates with the cellular malfunction.
The user is not allowed to open up the addresses and panel on the process, neither Take note: machine disassemble is allowed. To make sure the technique overall performance and safety, only Mindray engineers or engineers licensed by Mindray can complete servicing.
Get a whole and extended perspective with the anatomical construction via panoramic imaging coupled with velocity sign and ahead/backward scan capacity making scanning much easier, smoother and even more controllable.
This guide may perhaps referring to data protected by copyright or patents and won't convey any license underneath the patent legal rights or copyright of Mindray, or of Other folks. Web site 9: Statement
Click on Agree and Proceed to simply accept cookies and go straight to the positioning or click on More details to find out specific descriptions of the types of cookies and pick out regardless of whether to simply accept specified cookies though on the website.
Once you stop the scanning and the impression seize, you'll want to energy off the process and disconnect the system from your AC power offer, then pull out AC power cables. Website page 109: Battery Connecting Board
Page a hundred forty five Clean control panel Equipment: dry tender fabric, mild soapy water System: Use dry gentle cloth to clean the area in the technique. If the method is dirty, moisten the tender cloth with moderate soapy h2o and wipe off any stains. Use dry tender fabric to remove any dampness and allow all tricky surfaces to totally air-dry. Web site 146: Cleanse The Peripherals
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
iZoom™ permits exact viewing of graphic from length iWorks™ Protocol allows standardize workflow and decrease Test times
5.2.three Geometric positioning precision Longitudinal geometric positioning accuracy Take a look at Phase: Do changes as the way in screening the most depth. Document the space by 20mm Just about every phase within the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest mistake (to 20mm), estimate the precision using the formulation underneath The measurement caliper ought to be positioned for the higher edge of the focus on, Observe:... Page seventy nine Transverse geometric positioning precision Exam Step: Go over the scan surface area from the phantom with water or pair gel, gently Make contact with the probe Along with the scan floor Change the depth, earning the transverse targets to be exhibited during the impression. Alter the focus stage to be posited beside the transverse targets (the conventional is not really distinct) Adjust parameters like attain, TGC, building Every single transverse targets to get clearly shown. Page 80 five.5.2.4 Blackout Area Exam Phase: Include the scan floor in the phantom with h2o or couple gel, gently Speak to the probe Using the scan floor Regulate the depth at a reduced price, and established the focus at the nearest spot to the scan floor. Minimize the worth of parameters like AP, Acquire until eventually the background noise just could be viewed. Page 81: Computer software Enhance And Maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Find out improved diagnostic data via extended check out of the anatomical composition on all linear Dp50rb login probes
Cookies are essential to the appropriate functioning of a web page. To increase your encounter, we use cookies to recall log-in information and provide secure log-in, obtain figures to optimize site performance, and produce articles personalized on your pursuits.
After replacing the CPU module, essential file has to be generated once again in accordance with the new MAC handle and written into HDD of your equipment. Or else, the configuration function in the products are going to be lost. Just after taking away the CPU module, Eliminate panhead screws with washers (twelve M3X6) set on the primary device box, you may take off the board. Site 118 Determine 8-29 Disassemble the Control Panel Assembly (1) Keep the higher fringe of user interface assembly, and open up up the user interface. Determine eight-thirty Disassemble the User interface Assembly (2) Soon after removing a single countersunk head self-tapping screw PT3X10 preset about the user interface and acquire out the plug of the keyboard and the primary device connecting cables, you may take away the user interface assembly.
A smart new condition, Increased mobility and convenient Procedure make DP-fifty compatible for all clinical configurations.